SparseCT: System concept and design of multislit collimators

Baiyu Chen, Erich Kobler, Matthew J Muckley, Aaron D Sodickson, Thomas O’Donnell, Thomas Flohr, Bernahrd Schmidt, Daniel K Sodickson, Ricardo Otazo

Research output: Contribution to journalArticleResearchpeer-review

Abstract


Purpose
SparseCT, an undersampling scheme for compressed sensing (CS) computed tomography (CT), has been proposed to reduce radiation dose by acquiring undersampled projection data from clinical CT scanners (Koesters et al. in, SparseCT: Interrupted‐Beam Acquisition and Sparse Reconstruction for Radiation Dose Reduction; 2017). SparseCT partially blocks the x‐ray beam with a multislit collimator (MSC) to perform a multidimensional undersampling along the view and detector row dimensions. SparseCT undersamples the projection data within each view and moves the MSC along the z‐direction during gantry rotation to change the undersampling pattern. It enables reconstruction of images from undersampled data using CS algorithms. The purpose of this work is to design the spacing and width of the MSC slits and the MSC motion patterns based on beam separation, undersampling efficiency …
Original languageEnglish
Pages (from-to)2589-2599
JournalMedical physics
Volume46
Issue number6
DOIs
Publication statusPublished - 2019

Fingerprint

X-Ray Computed Tomography Scanners
Radiation
Computer-Assisted Image Processing
Tomography
X-Rays

Cite this

Chen, B., Kobler, E., Muckley, M. J., D Sodickson, A., O’Donnell, T., Flohr, T., ... Otazo, R. (2019). SparseCT: System concept and design of multislit collimators. Medical physics, 46(6), 2589-2599. https://doi.org/10.1002/mp.13544

SparseCT: System concept and design of multislit collimators. / Chen, Baiyu; Kobler, Erich; Muckley, Matthew J; D Sodickson, Aaron; O’Donnell, Thomas; Flohr, Thomas; Schmidt, Bernahrd; K Sodickson, Daniel; Otazo, Ricardo.

In: Medical physics, Vol. 46, No. 6, 2019, p. 2589-2599.

Research output: Contribution to journalArticleResearchpeer-review

Chen, B, Kobler, E, Muckley, MJ, D Sodickson, A, O’Donnell, T, Flohr, T, Schmidt, B, K Sodickson, D & Otazo, R 2019, 'SparseCT: System concept and design of multislit collimators' Medical physics, vol. 46, no. 6, pp. 2589-2599. https://doi.org/10.1002/mp.13544
Chen B, Kobler E, Muckley MJ, D Sodickson A, O’Donnell T, Flohr T et al. SparseCT: System concept and design of multislit collimators. Medical physics. 2019;46(6):2589-2599. https://doi.org/10.1002/mp.13544
Chen, Baiyu ; Kobler, Erich ; Muckley, Matthew J ; D Sodickson, Aaron ; O’Donnell, Thomas ; Flohr, Thomas ; Schmidt, Bernahrd ; K Sodickson, Daniel ; Otazo, Ricardo. / SparseCT: System concept and design of multislit collimators. In: Medical physics. 2019 ; Vol. 46, No. 6. pp. 2589-2599.
@article{74c0dc05705844b0a9cb7fe8c462f2c4,
title = "SparseCT: System concept and design of multislit collimators",
abstract = "PurposeSparseCT, an undersampling scheme for compressed sensing (CS) computed tomography (CT), has been proposed to reduce radiation dose by acquiring undersampled projection data from clinical CT scanners (Koesters et al. in, SparseCT: Interrupted‐Beam Acquisition and Sparse Reconstruction for Radiation Dose Reduction; 2017). SparseCT partially blocks the x‐ray beam with a multislit collimator (MSC) to perform a multidimensional undersampling along the view and detector row dimensions. SparseCT undersamples the projection data within each view and moves the MSC along the z‐direction during gantry rotation to change the undersampling pattern. It enables reconstruction of images from undersampled data using CS algorithms. The purpose of this work is to design the spacing and width of the MSC slits and the MSC motion patterns based on beam separation, undersampling efficiency …",
author = "Baiyu Chen and Erich Kobler and Muckley, {Matthew J} and {D Sodickson}, Aaron and Thomas O’Donnell and Thomas Flohr and Bernahrd Schmidt and {K Sodickson}, Daniel and Ricardo Otazo",
year = "2019",
doi = "10.1002/mp.13544",
language = "English",
volume = "46",
pages = "2589--2599",
journal = "Medical physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SparseCT: System concept and design of multislit collimators

AU - Chen, Baiyu

AU - Kobler, Erich

AU - Muckley, Matthew J

AU - D Sodickson, Aaron

AU - O’Donnell, Thomas

AU - Flohr, Thomas

AU - Schmidt, Bernahrd

AU - K Sodickson, Daniel

AU - Otazo, Ricardo

PY - 2019

Y1 - 2019

N2 - PurposeSparseCT, an undersampling scheme for compressed sensing (CS) computed tomography (CT), has been proposed to reduce radiation dose by acquiring undersampled projection data from clinical CT scanners (Koesters et al. in, SparseCT: Interrupted‐Beam Acquisition and Sparse Reconstruction for Radiation Dose Reduction; 2017). SparseCT partially blocks the x‐ray beam with a multislit collimator (MSC) to perform a multidimensional undersampling along the view and detector row dimensions. SparseCT undersamples the projection data within each view and moves the MSC along the z‐direction during gantry rotation to change the undersampling pattern. It enables reconstruction of images from undersampled data using CS algorithms. The purpose of this work is to design the spacing and width of the MSC slits and the MSC motion patterns based on beam separation, undersampling efficiency …

AB - PurposeSparseCT, an undersampling scheme for compressed sensing (CS) computed tomography (CT), has been proposed to reduce radiation dose by acquiring undersampled projection data from clinical CT scanners (Koesters et al. in, SparseCT: Interrupted‐Beam Acquisition and Sparse Reconstruction for Radiation Dose Reduction; 2017). SparseCT partially blocks the x‐ray beam with a multislit collimator (MSC) to perform a multidimensional undersampling along the view and detector row dimensions. SparseCT undersamples the projection data within each view and moves the MSC along the z‐direction during gantry rotation to change the undersampling pattern. It enables reconstruction of images from undersampled data using CS algorithms. The purpose of this work is to design the spacing and width of the MSC slits and the MSC motion patterns based on beam separation, undersampling efficiency …

U2 - 10.1002/mp.13544

DO - 10.1002/mp.13544

M3 - Article

VL - 46

SP - 2589

EP - 2599

JO - Medical physics

JF - Medical physics

SN - 0094-2405

IS - 6

ER -