Mirrored power distribution network noise injection for soft failure root cause analysis

Suyu Yang, Benjamin Orr, David Pommerenke, Hideki Shumiya, Junji Maeshima, Taketoshi Sekine, Yuzo Takita, Kenji Araki

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

In this paper a method for separating local soft-failures from distant errors related to noise on the power distribution network (PDN) is demonstrated. Two approaches are used which duplicate the noise on a PDN caused by some intentional injection onto a second system where the intentional injection is not present.

Original languageEnglish
Title of host publicationElectrical Overstress/Electrostatic Discharge Symposium Proceedings 2016, EOS/ESD 2016
PublisherESD Association
ISBN (Electronic)9781585372898
DOIs
Publication statusPublished - 14 Oct 2016
Externally publishedYes
Event38th Electrical Overstress/Electrostatic Discharge Symposium, EOS/ESD 2016 - Garden Grove (Anaheim), United States
Duration: 11 Sep 201616 Sep 2016

Publication series

NameElectrical Overstress/Electrostatic Discharge Symposium Proceedings
Volume2016-October
ISSN (Print)0739-5159

Conference

Conference38th Electrical Overstress/Electrostatic Discharge Symposium, EOS/ESD 2016
CountryUnited States
CityGarden Grove (Anaheim)
Period11/09/1616/09/16

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Fingerprint Dive into the research topics of 'Mirrored power distribution network noise injection for soft failure root cause analysis'. Together they form a unique fingerprint.

  • Cite this

    Yang, S., Orr, B., Pommerenke, D., Shumiya, H., Maeshima, J., Sekine, T., ... Araki, K. (2016). Mirrored power distribution network noise injection for soft failure root cause analysis. In Electrical Overstress/Electrostatic Discharge Symposium Proceedings 2016, EOS/ESD 2016 [7592564] (Electrical Overstress/Electrostatic Discharge Symposium Proceedings; Vol. 2016-October). ESD Association. https://doi.org/10.1109/EOSESD.2016.7592564