Mirrored power distribution network noise injection for soft failure root cause analysis

Suyu Yang, Benjamin Orr, David Pommerenke, Hideki Shumiya, Junji Maeshima, Taketoshi Sekine, Yuzo Takita, Kenji Araki

Research output: Chapter in Book/Report/Conference proceedingConference paperpeer-review

Abstract

In this paper a method for separating local soft-failures from distant errors related to noise on the power distribution network (PDN) is demonstrated. Two approaches are used which duplicate the noise on a PDN caused by some intentional injection onto a second system where the intentional injection is not present.

Original languageEnglish
Title of host publicationElectrical Overstress/Electrostatic Discharge Symposium Proceedings 2016, EOS/ESD 2016
PublisherESD Association
ISBN (Electronic)9781585372898
DOIs
Publication statusPublished - 14 Oct 2016
Externally publishedYes
Event38th Annual Electrical Overstress/Electrostatic Discharge Symposium: EOS/ESD 2016 - Garden Grove (Anaheim), United States
Duration: 11 Sept 201616 Sept 2016

Publication series

NameElectrical Overstress/Electrostatic Discharge Symposium Proceedings
Volume2016-October
ISSN (Print)0739-5159

Conference

Conference38th Annual Electrical Overstress/Electrostatic Discharge Symposium
Country/TerritoryUnited States
CityGarden Grove (Anaheim)
Period11/09/1616/09/16

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Mirrored power distribution network noise injection for soft failure root cause analysis'. Together they form a unique fingerprint.

Cite this