Impacts of Voltage Dips on the Behavior of Single Phase Induction Machines

Research output: Contribution to conferencePosterResearchpeer-review

Abstract

Voltage dips caused by faults in the power supply, change the behavior of single phase induction machines because transient currents and torques occur. In order to find an optimal disconnecting and restart time, the effects on the machine and the process must be determined. The effects of such voltage dips on the transient behavior depend on the chosen start circuit of the machine. In this paper the effects of different voltage dips and load conditions are analyzed by 2D-FEM calculations. First, the 2D-FEM results are compared with the results of measurements on a motor test stand. Different strategies of restarting are
derived from the analyzed results and the chosen start circuit of the machine.
Original languageEnglish
Pages452
Number of pages457
Publication statusPublished - 2016
EventPower Electronics, Electrical Drives, Automation and Motion - Capri, Italy
Duration: 22 Jun 201624 Jun 2016

Conference

ConferencePower Electronics, Electrical Drives, Automation and Motion
Abbreviated titleSPEEDAM 2016
CountryItaly
CityCapri
Period22/06/1624/06/16

Cite this

Bacher, J. P., & Mütze, A. (2016). Impacts of Voltage Dips on the Behavior of Single Phase Induction Machines. 452. Poster session presented at Power Electronics, Electrical Drives, Automation and Motion , Capri, Italy.

Impacts of Voltage Dips on the Behavior of Single Phase Induction Machines. / Bacher, Johann Peter; Mütze, Annette.

2016. 452 Poster session presented at Power Electronics, Electrical Drives, Automation and Motion , Capri, Italy.

Research output: Contribution to conferencePosterResearchpeer-review

Bacher, JP & Mütze, A 2016, 'Impacts of Voltage Dips on the Behavior of Single Phase Induction Machines' Power Electronics, Electrical Drives, Automation and Motion , Capri, Italy, 22/06/16 - 24/06/16, pp. 452.
Bacher JP, Mütze A. Impacts of Voltage Dips on the Behavior of Single Phase Induction Machines. 2016. Poster session presented at Power Electronics, Electrical Drives, Automation and Motion , Capri, Italy.
Bacher, Johann Peter ; Mütze, Annette. / Impacts of Voltage Dips on the Behavior of Single Phase Induction Machines. Poster session presented at Power Electronics, Electrical Drives, Automation and Motion , Capri, Italy.457 p.
@conference{d22b9b46db5e43c6bc3319fcdb3d5145,
title = "Impacts of Voltage Dips on the Behavior of Single Phase Induction Machines",
abstract = "Voltage dips caused by faults in the power supply, change the behavior of single phase induction machines because transient currents and torques occur. In order to find an optimal disconnecting and restart time, the effects on the machine and the process must be determined. The effects of such voltage dips on the transient behavior depend on the chosen start circuit of the machine. In this paper the effects of different voltage dips and load conditions are analyzed by 2D-FEM calculations. First, the 2D-FEM results are compared with the results of measurements on a motor test stand. Different strategies of restarting arederived from the analyzed results and the chosen start circuit of the machine.",
author = "Bacher, {Johann Peter} and Annette M{\"u}tze",
year = "2016",
language = "English",
pages = "452",
note = "Power Electronics, Electrical Drives, Automation and Motion , SPEEDAM 2016 ; Conference date: 22-06-2016 Through 24-06-2016",

}

TY - CONF

T1 - Impacts of Voltage Dips on the Behavior of Single Phase Induction Machines

AU - Bacher, Johann Peter

AU - Mütze, Annette

PY - 2016

Y1 - 2016

N2 - Voltage dips caused by faults in the power supply, change the behavior of single phase induction machines because transient currents and torques occur. In order to find an optimal disconnecting and restart time, the effects on the machine and the process must be determined. The effects of such voltage dips on the transient behavior depend on the chosen start circuit of the machine. In this paper the effects of different voltage dips and load conditions are analyzed by 2D-FEM calculations. First, the 2D-FEM results are compared with the results of measurements on a motor test stand. Different strategies of restarting arederived from the analyzed results and the chosen start circuit of the machine.

AB - Voltage dips caused by faults in the power supply, change the behavior of single phase induction machines because transient currents and torques occur. In order to find an optimal disconnecting and restart time, the effects on the machine and the process must be determined. The effects of such voltage dips on the transient behavior depend on the chosen start circuit of the machine. In this paper the effects of different voltage dips and load conditions are analyzed by 2D-FEM calculations. First, the 2D-FEM results are compared with the results of measurements on a motor test stand. Different strategies of restarting arederived from the analyzed results and the chosen start circuit of the machine.

M3 - Poster

SP - 452

ER -