Comparison of the maximal slope method with SVD- and FT-deconvolution for the calculation of perfusion images in DSC-MRI of the brain

Rudolf Stollberger, G. Reishofer, C. Enzinger, F. Ebner, F. Fazekas

Research output: Chapter in Book/Report/Conference proceedingConference contributionResearchpeer-review

Original languageEnglish
Title of host publicationProceedings ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective
Publisher.
Pages154-155
Publication statusPublished - 2004

Cite this

Stollberger, R., Reishofer, G., Enzinger, C., Ebner, F., & Fazekas, F. (2004). Comparison of the maximal slope method with SVD- and FT-deconvolution for the calculation of perfusion images in DSC-MRI of the brain. In Proceedings ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective (pp. 154-155). ..

Comparison of the maximal slope method with SVD- and FT-deconvolution for the calculation of perfusion images in DSC-MRI of the brain. / Stollberger, Rudolf; Reishofer, G.; Enzinger, C.; Ebner, F.; Fazekas, F.

Proceedings ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective. ., 2004. p. 154-155.

Research output: Chapter in Book/Report/Conference proceedingConference contributionResearchpeer-review

Stollberger, R, Reishofer, G, Enzinger, C, Ebner, F & Fazekas, F 2004, Comparison of the maximal slope method with SVD- and FT-deconvolution for the calculation of perfusion images in DSC-MRI of the brain. in Proceedings ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective. ., pp. 154-155.
Stollberger R, Reishofer G, Enzinger C, Ebner F, Fazekas F. Comparison of the maximal slope method with SVD- and FT-deconvolution for the calculation of perfusion images in DSC-MRI of the brain. In Proceedings ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective. . 2004. p. 154-155
Stollberger, Rudolf ; Reishofer, G. ; Enzinger, C. ; Ebner, F. ; Fazekas, F. / Comparison of the maximal slope method with SVD- and FT-deconvolution for the calculation of perfusion images in DSC-MRI of the brain. Proceedings ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective. ., 2004. pp. 154-155
@inproceedings{5ec1383269624b51b9f76b82dc09c370,
title = "Comparison of the maximal slope method with SVD- and FT-deconvolution for the calculation of perfusion images in DSC-MRI of the brain",
author = "Rudolf Stollberger and G. Reishofer and C. Enzinger and F. Ebner and F. Fazekas",
year = "2004",
language = "English",
pages = "154--155",
booktitle = "Proceedings ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective",
publisher = ".",

}

TY - GEN

T1 - Comparison of the maximal slope method with SVD- and FT-deconvolution for the calculation of perfusion images in DSC-MRI of the brain

AU - Stollberger, Rudolf

AU - Reishofer, G.

AU - Enzinger, C.

AU - Ebner, F.

AU - Fazekas, F.

PY - 2004

Y1 - 2004

M3 - Conference contribution

SP - 154

EP - 155

BT - Proceedings ISMRM Workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective

PB - .

ER -