A programmable biopotential aquisition front-end with a resistance-free current balancing instrumentation amplifier

Paul Faragó, Robert Groza, Sorin Hintea, Peter Söser

Research output: Contribution to journalArticleResearchpeer-review

Abstract

The development of wearable biomedical equipment benefits from low-power and low-voltage circuit techniques for reduced battery size and battery, or even battery-less, operation. This paper proposes a fully-differential low-power resistance-free programmable instrumentation amplifier for the analog front-end of biopotential monitoring systems. The proposed instrumentation amplifier implements the current balancing technique. Low power consumption is achieved with subthreshold biasing. To reduce chip area and enable integration, passive resistances have been replaced with active equivalents. Accordingly, the instrumentation amplifier gain is expressed as the ratio of two transconductance values. The proposed instrumentation amplifier exhibits two degrees of freedom: one to set the desired range and the other for finetuning of the voltage gain. The proposed IA is employed in a programmable biopotential acquisition front-end. The programmable frequency-selective behavior is achieved by having the lower cutoff frequency of a Gm-C Tow-Thomas biquad varied in a constant-C tuning approach. The proposed solutions and the programmability of the operation parameters to the specifications of particular bio-medical signals are validated on a 350nm CMOS process.

LanguageEnglish
Pages85-92
Number of pages8
JournalAdvances in Electrical and Computer Engineering
Volume18
Issue number2
DOIs
StatusPublished - 1 Jan 2018

Fingerprint

Biomedical equipment
Cutoff frequency
Transconductance
Electric potential
Electric power utilization
Tuning
Specifications
Networks (circuits)
Monitoring

Keywords

  • Analog processing circuits
  • Biomedical monitoring
  • Biomedical signal processing
  • Operational amplifiers
  • Programmable circuits

ASJC Scopus subject areas

  • Computer Science(all)
  • Electrical and Electronic Engineering

Cite this

A programmable biopotential aquisition front-end with a resistance-free current balancing instrumentation amplifier. / Faragó, Paul; Groza, Robert; Hintea, Sorin; Söser, Peter.

In: Advances in Electrical and Computer Engineering, Vol. 18, No. 2, 01.01.2018, p. 85-92.

Research output: Contribution to journalArticleResearchpeer-review

@article{f604b3175aa847edab447dc692b98a21,
title = "A programmable biopotential aquisition front-end with a resistance-free current balancing instrumentation amplifier",
abstract = "The development of wearable biomedical equipment benefits from low-power and low-voltage circuit techniques for reduced battery size and battery, or even battery-less, operation. This paper proposes a fully-differential low-power resistance-free programmable instrumentation amplifier for the analog front-end of biopotential monitoring systems. The proposed instrumentation amplifier implements the current balancing technique. Low power consumption is achieved with subthreshold biasing. To reduce chip area and enable integration, passive resistances have been replaced with active equivalents. Accordingly, the instrumentation amplifier gain is expressed as the ratio of two transconductance values. The proposed instrumentation amplifier exhibits two degrees of freedom: one to set the desired range and the other for finetuning of the voltage gain. The proposed IA is employed in a programmable biopotential acquisition front-end. The programmable frequency-selective behavior is achieved by having the lower cutoff frequency of a Gm-C Tow-Thomas biquad varied in a constant-C tuning approach. The proposed solutions and the programmability of the operation parameters to the specifications of particular bio-medical signals are validated on a 350nm CMOS process.",
keywords = "Analog processing circuits, Biomedical monitoring, Biomedical signal processing, Operational amplifiers, Programmable circuits",
author = "Paul Farag{\'o} and Robert Groza and Sorin Hintea and Peter S{\"o}ser",
year = "2018",
month = "1",
day = "1",
doi = "10.4316/AECE.2018.02011",
language = "English",
volume = "18",
pages = "85--92",
journal = "Advances in Electrical and Computer Engineering",
issn = "1582-7445",
publisher = "Stefan cel Mare University of Suceava",
number = "2",

}

TY - JOUR

T1 - A programmable biopotential aquisition front-end with a resistance-free current balancing instrumentation amplifier

AU - Faragó,Paul

AU - Groza,Robert

AU - Hintea,Sorin

AU - Söser,Peter

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The development of wearable biomedical equipment benefits from low-power and low-voltage circuit techniques for reduced battery size and battery, or even battery-less, operation. This paper proposes a fully-differential low-power resistance-free programmable instrumentation amplifier for the analog front-end of biopotential monitoring systems. The proposed instrumentation amplifier implements the current balancing technique. Low power consumption is achieved with subthreshold biasing. To reduce chip area and enable integration, passive resistances have been replaced with active equivalents. Accordingly, the instrumentation amplifier gain is expressed as the ratio of two transconductance values. The proposed instrumentation amplifier exhibits two degrees of freedom: one to set the desired range and the other for finetuning of the voltage gain. The proposed IA is employed in a programmable biopotential acquisition front-end. The programmable frequency-selective behavior is achieved by having the lower cutoff frequency of a Gm-C Tow-Thomas biquad varied in a constant-C tuning approach. The proposed solutions and the programmability of the operation parameters to the specifications of particular bio-medical signals are validated on a 350nm CMOS process.

AB - The development of wearable biomedical equipment benefits from low-power and low-voltage circuit techniques for reduced battery size and battery, or even battery-less, operation. This paper proposes a fully-differential low-power resistance-free programmable instrumentation amplifier for the analog front-end of biopotential monitoring systems. The proposed instrumentation amplifier implements the current balancing technique. Low power consumption is achieved with subthreshold biasing. To reduce chip area and enable integration, passive resistances have been replaced with active equivalents. Accordingly, the instrumentation amplifier gain is expressed as the ratio of two transconductance values. The proposed instrumentation amplifier exhibits two degrees of freedom: one to set the desired range and the other for finetuning of the voltage gain. The proposed IA is employed in a programmable biopotential acquisition front-end. The programmable frequency-selective behavior is achieved by having the lower cutoff frequency of a Gm-C Tow-Thomas biquad varied in a constant-C tuning approach. The proposed solutions and the programmability of the operation parameters to the specifications of particular bio-medical signals are validated on a 350nm CMOS process.

KW - Analog processing circuits

KW - Biomedical monitoring

KW - Biomedical signal processing

KW - Operational amplifiers

KW - Programmable circuits

UR - http://www.scopus.com/inward/record.url?scp=85047865716&partnerID=8YFLogxK

U2 - 10.4316/AECE.2018.02011

DO - 10.4316/AECE.2018.02011

M3 - Article

VL - 18

SP - 85

EP - 92

JO - Advances in Electrical and Computer Engineering

T2 - Advances in Electrical and Computer Engineering

JF - Advances in Electrical and Computer Engineering

SN - 1582-7445

IS - 2

ER -