Wide Frequency Range Impedance Measurement of a Li-ion Prismatic Cell for Power Line Communication Technique

Arash Pake Talei, Wolfgang A. Pribyl, Gunter Hofer

Publikation: Beitrag in Buch/Bericht/KonferenzbandBeitrag in einem Konferenzband

Abstract

This paper explains the proper way of measuring a prismatic li-ion battery cell which is used in electric vehicles. The challenges and the solution of connecting a battery cell to a vector network analyzer are discussed. It is shown how to properly measure, calculate and de-embed the parasitic components of the medium connector. At the end a prismatic cell is measured in a wide frequency range from 1MHz to 1GHz.

Originalspracheenglisch
TitelSMACD 2019 - 16th International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design, Proceedings
Herausgeber (Verlag)Institute of Electrical and Electronics Engineers
Seiten109-112
Seitenumfang4
ISBN (elektronisch)9781728112015
DOIs
PublikationsstatusVeröffentlicht - 1 Jul 2019
Veranstaltung16th International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design, SMACD 2019 - Lausanne, Schweiz
Dauer: 15 Jul 201918 Jul 2019

Publikationsreihe

NameSMACD 2019 - 16th International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design, Proceedings

Konferenz

Konferenz16th International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design, SMACD 2019
LandSchweiz
OrtLausanne
Zeitraum15/07/1918/07/19

ASJC Scopus subject areas

  • !!Computer Graphics and Computer-Aided Design
  • !!Electrical and Electronic Engineering
  • !!Safety, Risk, Reliability and Quality
  • !!Modelling and Simulation
  • !!Instrumentation

Fingerprint Untersuchen Sie die Forschungsthemen von „Wide Frequency Range Impedance Measurement of a Li-ion Prismatic Cell for Power Line Communication Technique“. Zusammen bilden sie einen einzigartigen Fingerprint.

  • Dieses zitieren

    Talei, A. P., Pribyl, W. A., & Hofer, G. (2019). Wide Frequency Range Impedance Measurement of a Li-ion Prismatic Cell for Power Line Communication Technique. in SMACD 2019 - 16th International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design, Proceedings (S. 109-112). [8795281] (SMACD 2019 - 16th International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design, Proceedings). Institute of Electrical and Electronics Engineers. https://doi.org/10.1109/SMACD.2019.8795281