Simulations and Experiments on Critical Operating Conditions with Total Harmonic Distortion

Titel in Übersetzung: Simulationen und Experimente bei kritischen Betriebsbedingungen mittels Klirrfaktoren

Kurt Mayer*, Viktor Hacker

*Korrespondierende/r Autor/-in für diese Arbeit

Publikation: KonferenzbeitragAbstractBegutachtung

Abstract

Online monitoring systems for polymer electrolyte fuel cells in vehicles are used to increase the reliability and service life of fuel cell systems. Currently, cell voltage monitoring (CVM) and electrochemical impedance spectroscopy (EIS) are primarily used for this purpose. However, CVM requires extensive wiring and often cannot distinguish between the causes of sudden voltage changes caused by critical conditions. EIS is slow and can preferably be used in the high frequency range for online monitoring of membrane resistance. Another challenge arises from the time invariance and linearity of the transfer function, so that it cannot be applied for transient studies.
In this talk, new developments of the innovative online monitoring technique based on Total Harmonic Distortion (THD), will be presented. In THD, the fuel cell is excited with a sinusoidal current at a certain frequency and the voltage response is evaluated. The harmonic distortions caused by the nonlinearity of the polarization curve are interpreted [1] and the frequency with the highest harmonic content is chosen in order to identify a certain critical condition. Discussed is the distinction of different critical operating states (flooding, drying of the membrane, and degradation of the catalyst layer) in models and in experiments. Recent experiments showed that not only in the low frequency region high harmonic content can be detected for flooding and drying events, but also at frequencies above 1 kHz for catalyst degradation.
In a Dynamic Large Signal Equivalent Circuit (DLSEC) (Figure 1), all losses of a fuel cell are described by voltage or current sources that follow the Butler-Volmer Equation (jct,anode, ηct,cathode, ηPtO,formation) or a combination of the Nernst-Equation and Fick’s Law (ηmt). DLSEC is parameterized based on impedance measurements and data from operating points [2] by using an evolutionary fitting algorithm in Python. The actual simulations are performed in the software LTSPICE (Analog Devices). DLSECs can simulate polarization curves, impedance spectra and THD. The new platinum oxide formation part has been added to the existing models. This new feature describes the induction loop at very low frequencies in the impedance spectra, completing the fuel cell characterization.

References:
[1] E. Ramschak, V. Peinecke, P. Prenninger, T. Schaffer, and V. Hacker, “Detection of fuel cell critical status by stack voltage analysis,” J. Power Sources, vol. 157, no. 2, pp. 837–840, Jul. 2006, doi: 10.1016/j.jpowsour.2006.01.009.
[2] S. Weinberger, S. Trattner, B. Cermenek, A. Schenk, C. Grimmer, and V. Hacker, “Generic tool for the simulation of electrochemical fuel cell monitoring techniques,” J. Energy Storage, vol. 12, pp. 319–331, Aug. 2017, doi: 10.1016/j.est.2017.05.010.
Titel in ÜbersetzungSimulationen und Experimente bei kritischen Betriebsbedingungen mittels Klirrfaktoren
Originalspracheenglisch
PublikationsstatusAngenommen/In Druck - 19 Mai 2021
Veranstaltung72nd Annual ISE Meeting - International Conference Center Jeju (ICC Jeju), Hybrider Event, Südkorea
Dauer: 29 Aug. 20213 Sept. 2021
https://annual72.ise-online.org/index.php

Konferenz

Konferenz72nd Annual ISE Meeting
Land/GebietSüdkorea
OrtHybrider Event
Zeitraum29/08/213/09/21
Internetadresse

Fields of Expertise

  • Mobility & Production

Fingerprint

Untersuchen Sie die Forschungsthemen von „Simulationen und Experimente bei kritischen Betriebsbedingungen mittels Klirrfaktoren“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren