Impacts of Voltage Dips on the Behavior of Single Phase Induction Machines

Publikation: KonferenzbeitragPosterBegutachtung

Abstract

Voltage dips caused by faults in the power supply, change the behavior of single phase induction machines because transient currents and torques occur. In order to find an optimal disconnecting and restart time, the effects on the machine and the process must be determined. The effects of such voltage dips on the transient behavior depend on the chosen start circuit of the machine. In this paper the effects of different voltage dips and load conditions are analyzed by 2D-FEM calculations. First, the 2D-FEM results are compared with the results of measurements on a motor test stand. Different strategies of restarting are
derived from the analyzed results and the chosen start circuit of the machine.
Originalspracheenglisch
Seiten452
Seitenumfang457
PublikationsstatusVeröffentlicht - 2016
VeranstaltungPower Electronics, Electrical Drives, Automation and Motion - Capri, Italien
Dauer: 22 Juni 201624 Juni 2016

Konferenz

KonferenzPower Electronics, Electrical Drives, Automation and Motion
KurztitelSPEEDAM 2016
Land/GebietItalien
OrtCapri
Zeitraum22/06/1624/06/16

Dieses zitieren